Enter/Exit Programming Mode EAS Features
198 Magellan™ 9300i / 9400i Scanners
EAS Pre-Read Time
This feature specifies the time duration that must elapse before reading a label
once an EAS tag is sensed.
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code, Set EAS Pre-Read Time on page 198 below. You’ll need
to cover any unused bar codes on this and the facing page to ensure that
the scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the Keypad on page 461 in Appendix C
that represent the desired duration. The selectable range is 000-255,
which is the duration in 10-millisecond increments. Pad all single and
double digit numbers with leading zeros to yield a three-digit entry (000-
255).
Examples:
005 = 50ms
040 = 400ms
250 = 2,500ms (2.5 seconds)
4. The scanner will automatically exit Programming Mode when the appro-
priate amount of digits have been scanned.
Set EAS Pre-Read Time
Default setting for this feature is:
19 = 250ms
DEFAULT