EasyManua.ls Logo

Datalogic Magellan 9300i - Code 39 Start Stop Character Transmission

Datalogic Magellan 9300i
520 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Enter/Exit Programming Mode
Product Reference Guide
351
Code 39 Start Stop Character Transmission
Enables/disables transmission of Code 39 start and stop characters.
To set this feature:
1. Scan the ENTER/EXIT Programming Mode bar code.
2. Scan either the enable or disable bar code below. You’ll need to cover any
unused bar codes on this and the facing page to ensure that the scanner
reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the ENTER/EXIT Pro-
gramming Mode bar code.
NOTE
This item is ignored when the advanced feature, Full Label
Edit, is enabled
Code 39 Start Stop Character Transmission = Disable
Code 39 Start Stop Character Transmission = Enable
DEFAULT
022400(CR)
022401(CR)

Table of Contents

Other manuals for Datalogic Magellan 9300i

Related product manuals