Enter/Exit Programming Mode
Product Reference Guide
349
DataBar Expanded Reverse Retry
Enables/disables the reading of out of specification labels where the last row
has been printed in reverse.
• When enabled, DataBar Expanded Stacked labels that have the last row
incorrectly printed in reverse will be re-decoded.
• When disabled, DataBar Expanded Stacked labels that have the last row
incorrectly printed in reverse will not be read.
To set this feature:
1. Scan the ENTER/EXIT Programming Mode bar code.
2. Scan your selection from the bar codes below. You’ll need to cover any
unused bar codes on this and the facing page to ensure that the scanner
reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the ENTER/EXIT Pro-
gramming Mode bar code.
DataBar Expanded Reverse Retry = Disable
DataBar Expanded Reverse Retry = Enable