Enter/Exit Programming Mode Interface Related Features
244 Magellan™ 9300i / 9400i Scanners
Single Cable RS-232 Scanner Only Protocol
This sets the type of interface protocol that will be used in Single Cable RS-232.
Options are:
Scanner/scale RS-232 protocol
Scanner only RS-232 protocol
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code below representing the desired option. You’ll need to
cover any unused bar codes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the Enter/Exit Pro-
gramming Mode bar code.
Single Cable RS-232 Scanner Only Protocol = Scanner/scale
RS-232 protocol
Single Cable RS-232 Scanner Only Protocol = Scanner Only
protocol
DEFAULT
047C00(CR)
047C01(CR)