Scanning Features Enter/Exit Programming Mode
Product Reference Guide
135
Sleep Mode Timer
This feature specifies the amount of time of inactivity (with no label reads)
before the scanner enters sleep mode.
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code, Set Sleep Mode Timer on page 135 below. You’ll need
to cover any unused bar codes on this and the facing page to ensure that
the scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the Keypad on page 461 in Appendix C
that represent the desired time interval. The selectable range is 000-255
in 15 second increments. Pad all numbers with leading zeros to yield a
three-digit entry (000-255).
4. Scan the Enter/Exit Programming Mode bar code to exit Programming
Mode.
Set Sleep Mode Timer
Default setting for this feature is: 5 minutes
DEFAULT