EasyManua.ls Logo

Datalogic Magellan 9300i - MSI Check Character Transmission

Datalogic Magellan 9300i
520 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Enter/Exit Programming Mode
Product Reference Guide
407
MSI Check Character Transmission
Enables/disables transmission of optional MSI check characters.
To set this feature:
1. Scan the ENTER/EXIT Programming Mode bar code.
2. Scan either the enable or disable bar code below. You’ll need to cover any
unused bar codes on this and the facing page to ensure that the scanner
reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the ENTER/EXIT Pro-
gramming Mode bar code.
NOTE
This feature applies only when MSI Check Character Cal-
culation on page 405 is enabled. This item is ignored
when the advanced feature, Full Label Edit, is enabled.
MSI Check Character Transmission = Disable
MSI Check Character Transmission = Enable
00BE00(CR)
00BE01(CR)
DEFAULT

Table of Contents