Symptom:
AUX FAN R EL AY CO NT R O L SHO R T E D L OW (AC TI VE )
POSSIBLE CAUSES
A/C AUXILIARY FAN RE LAY
A/C AUXILIARY FAN RE LAY HIGH SIDE CON TROL CIRCUIT SHORTE D TO GROUND
A/C AUXILIARY FAN RE LAY HIGH SIDE CON TROL CIRCUIT SHORTE D TO GROUND CIRCUIT
AUTOMATIC TE MPE RATURE CONTROL (ATC)
A/C AUXILIARY FAN RE LAY HIGH SIDE CON TROL CKT SH ORTE D TO SE NSOR GROUND CKT
TE S T ACTION AP PLICAB ILITY
1 Tur n th e ign it ion off.
In st all a su bst it u t e r ela y in pla ce of t h e A/C Au xilia r y F a n Rela y.
NOTE:All of the following criteria must be met in order to successfully run
the ATC Function Test.
Pla ce th e sh ift lever in Pa r k.
Tur n th e ign it ion on .
Wit h th e DRBIII", r ecor d a nd er a se ATC DTC’s.
St a r t th e engin e. Allow th e en gin e t o rea ch n orm a l opera t ing tem per a t u r e.
Set t he blower to high speed.
Pr ess t h e Air Con dit ion in g swit ch On .
Wit h t he DRBIII", ver ify th a t t he am bien t t em per at u r e is a bove 59°F (15°C), th e
refr iger a n t pr essu r e is bet ween 29 a n d 348 P SI (2 a n d 24 ba r ), t h e eva por a t or
tem per a t ur e is a bove 36.5°F (2.5°C), a n d t h e coola n t t em per a t ur e is a bove 158°F
(70°C).
Wit h t h e DRBIII" in Aut om a t ic Tem pera t u r e Cont r ol (ATC), select Syst em Tests an d
select ATC F u n ct ion Test . Wh en t h e ATC Fu n ct ion Test is complet e, pr oceed a s
follows:
Wit h th e DRBIII", r ea d t he a ct ive ATC DTCs.
Does t h e DRBIII" displa y: AUX FAN RE LAY CONTROL SHORTE D LOW?
All
Ye s → Go To 2
No → Repla ce t h e origin a l A/C Au xilia r y F a n Rela y in accor da n ce wit h
th e Ser vice In form a t ion .
Per for m BODY VERIFICATION TE ST - VE R 1.
2 Tur n th e ign it ion off.
Rem ove t h e su bst it u t e A/C Au xilia r y F a n Rela y fr om th e rela y cen t er.
Discon n ect t he Aut om a t ic Tem pera t u r e Con t r ol (ATC) C1 ha r n ess conn ect or.
Mea su r e th e r esist a n ce bet ween gr ou n d a n d th e A/C Au xilia ry Fa n Rela y H igh Side
Con t r ol cir cuit .
Is t h e resista n ce below 10K ohm s?
All
Ye s → Repa ir t h e A/C Au xilia r y F a n Relay H igh Side Con t r ol cir cu it for
a sh ort t o gr ou n d. Rein st a ll th e or igin a l A/C Auxilia r y F a n Rela y.
Per for m BODY VERIFICATION TE ST - VE R 1.
No → Go To 3