Symptom:
IN S TR U MEN T CLU S TE R IN TE RN AL FAILU R E B 1053
POSSIBLE CAUSES
CAN BU S FAILU RE
INSTRUMENT CLUSTER
TE S T ACTION AP PLICAB ILITY
1 If th is fa u lt is pr esen t , sca n th e E n gin e Con t r ol Modu le a n d/or Tra n sm ission Con t r ol
Modu le for an y CAN Bu s r ela t ed fa u lt s.
Are a n y CAN Bu s Rela t ed fa u lt s pr esen t ?
All
Ye s → Refer to th e sym pt om list for repa ir in for m a t ion r ela tin g t o CAN
Bu s fa ilu r es.
Per for m BODY VERIFICATION TE ST - VE R 1.
No → Go To 2
2 Wit h th e DRBIII",eraseDTCs.
Tur n th e ign it ion off, wa it 10 secon ds, th en t u r n th e ign it ion on .
Wit h th e DRBIII",readDTCs.
Does t h e DRBIII" read: B1053 Instrument Cluster Internal Failure?
All
Vie w Rep a ir
Repla ce t h e In st r u m en t Clu st er in a ccor da n ce wit h th e Ser vice
In for m a t ion .
Per for m BODY VERIFICATION TE ST - VE R 1.
186
INSTRUMENT CLUSTER