Symptom:
RKE INTERFACE CIRCU IT SHORT TO VOLTAGE - CTM
Wh e n Mo n i to re d a n d S e t Co n d it i o n :
RKE INTERFACE CIRCU IT S H ORT TO VOLTAGE - CTM
Wh en Mon itor ed: Wh en ever t h e ba t ter y volt age is above 10.0 volt s a nd t he modu le is
conn ect ed.
Set Condit ion : If t h e CTM mon it or s a volt a ge on t h e RKE In t er fa ce cir cu it for over 30
secon ds, th is code will set .
POSSIBLE CAUSES
CE NTRAL TIME R MODULE SHORT TO VOLTAGE
RKE INTE RFACE WIRE SH ORT TO VOLTAGE
SKREE M SHORTED
TE S T ACTION AP PLICAB ILITY
1 Tur n th e ign it ion off.
Discon n ect t he Cen t ra l Tim er Modu le C1 con n ect or.
Mea su r e th e volt a ge bet ween gr ou nd a n d t h e RKE Int er fa ce cir cu it .
Is t h er e an y volt a ge pr esen t ?
All
Ye s → Go To 2
No → Repla ce th e Cen t r a l Tim er Module.
Per for m BODY VERIFICATION TE ST - VE R 1.
2 Discon n ect t he Cen t ra l Tim er Modu le C1 con n ect or.
Discon n ect t he SKRE E M conn ect or.
Tur n th e ign it ion on .
Mea su r e th e volt a ge bet ween gr ou nd a n d t h e RKE Int er fa ce cir cu it .
Is t h er e an y volt a ge pr esen t ?
All
Ye s → Repa ir t h e RKE In t er fa ce cir cu it for a sh or t to volt a ge.
Per for m BODY VERIFICATION TE ST - VE R 1.
No → Repla ce th e Sen t r y Key Rem ot E En t r y Modu le.
Per for m BODY VERIFICATION TE ST - VE R 1.
205
POWER DOOR LOCK S/RK E