TE S T ACTION AP PLICAB ILITY
3 Discon n ect t he Cen t ra l Tim er Modu le C1 con n ect or.
Discon n ect t he SKRE E M conn ect or.
Mea su r e th e resista n ce between gr ou n d a n d t h e RKE Int er fa ce cir cu it .
Is t h e resista n ce below 20000.0 ohm s?
All
Ye s → Repa ir t h e RKE In t er fa ce cir cu it for a sh or t to gr oun d.
Per for m BODY VERIFICATION TE ST - VE R 1.
No → Go To 4
4 Discon n ect t he Cen t ra l Tim er Modu le C1 con n ect or.
Discon n ect t he SKRE E M conn ect or.
Mea su r e t h e resist a nce of th e RKE In ter fa ce circu it bet ween t h e SKRE E M con n ect or
an d t h e CTM C1 conn ect or..
Is t h e resista n ce below 5.0 ohm s?
All
Ye s → Repla ce th e Cent r a l Tim er Modu le.
Per for m BODY VERIFICATION TE ST - VE R 1.
No → Repa ir th e RKE In t er fa ce cir cu it for an open .
Per for m BODY VERIFICATION TE ST - VE R 1.
204
POWER DOOR LOCK S/RK E
RKE INTERFACE CIRCUIT SHORT TO GROUND - SKREEM — Co n t i n u ed