TE S T ACTION AP PLICAB ILITY
3 Tur n th e ign it ion off.
NOTE: Ch e c k c o n n e c to rs - Cle an /re pa i r a s n e c e ss a ry.
Discon n ect t he Aut om a t ic Tem pera t u r e Con t r ol (ATC) C1 ha r n ess conn ect or.
Discon n ect t he Cir cu la t ion P u m p ha r n ess con n ect or.
Mea su r e th e r esist a n ce of t h e Cir cu lat ion P u m p Con t r ol cir cuit bet ween th e
Aut om a t ic Tem per a t u r e Con t r ol (ATC) C1 h a r n ess con nect or an d th e Cir cu la t ion
Pu m p h a r n ess con n ect or.
Is t h e resista n ce below 5.0 ohm s?
All
Ye s → Go To 4
No → Repa ir th e Cir cu la t ion P um p Con t r ol circu it for an open .
Per for m BODY VERIFICATION TE ST - VE R 1.
4 Tur n th e ign it ion off.
NOTE: Ch e c k c o n n e c to rs - Cle an /re pa i r a s n e c e ss a ry.
Discon n ect t he Cir cu la t ion P u m p ha r n ess con n ect or.
Mea su r e th e resista n ce between gr ou n d a n d t h e Gr ou n d cir cu it .
Is t h e resista n ce below 5.0 ohm s?
All
Ye s → Repla ce th e Aut om a t ic Tem per a t u r e Con t r ol (ATC) in a ccor da nce
wit h th e Ser vice In for m a t ion .
Per for m BODY VERIFICATION TE ST - VE R 1.
No → Repa ir th e Gr oun d cir cuit for an open .
Per for m BODY VERIFICATION TE ST - VE R 1.
153
HEAT IN G & A/C
CIRC PU MP CON TR OL H IGH OR OPE N (ACTIVE ) — Co n t inued