TE S T ACTION AP PLICAB ILITY
2 Tur n th e ign it ion off.
NOTE: Ch e c k c o n n e c to rs - Cle an /re pa i r a s n e c e ss a ry.
Discon n ect t he Aut om a t ic Tem pera t u r e Con t r ol (ATC) C1 ha r n ess conn ect or.
Tur n th e ign it ion on .
Mea su r e th e volt a ge of th e Wa t er Cycle Valve Con t r ol cir cuit .
Is t h e volt a ge above 0.2 volt s?
All
Ye s → Repa ir t h e Wat er Cycle Va lve Con t r ol cir cu it for a sh or t t o v olt a ge.
Per for m BODY VERIFICATION TE ST - VE R 1.
No → Repla ce th e Aut om a t ic Tem pera t u r e Cont r ol (ATC) in a ccorda n ce
wit h th e Ser vice In for m a t ion .
Per for m BODY VERIFICATION TE ST - VE R 1.
3 Tur n th e ign it ion off.
NOTE: Ch e c k c o n n e c to rs - Cle an /re pa i r a s n e c e ss a ry.
Discon n ect t he Aut om a t ic Tem pera t u r e Con t r ol (ATC) C1 ha r n ess conn ect or.
Discon n ect t he Wa t er Cycle Valve ha r n ess con n ect or.
Mea su r e t h e r esist a nce of th e Wa t er Cycle Va lve Con t r ol cir cu it bet ween t h e
Aut om a t ic Tem per a t u r e Con t r ol (ATC) C1 h a r n ess con n ect or a n d t h e Wat er Cycle
Valve ha r n ess con n ect or.
Is t h e resista n ce below 5.0 ohm s?
All
Ye s → Go To 4
No → Repa ir th e Wa t er Cycle Valve Con t r ol cir cu it for an open .
Per for m BODY VERIFICATION TE ST - VE R 1.
4 Tur n th e ign it ion off.
NOTE: Ch e c k c o n n e c to rs - Cle an /re pa i r a s n e c e ss a ry.
Discon n ect t he Wa t er Cycle Valve ha r n ess con n ect or.
Mea su r e th e resista n ce between gr ou n d a n d t h e Gr ou n d cir cu it .
Is t h e resista n ce below 5.0 ohm s?
All
Ye s → Repla ce th e Aut om a t ic Tem per a t u r e Con t r ol (ATC) in a ccor da nce
wit h th e Ser vice In for m a t ion .
Per for m BODY VERIFICATION TE ST - VE R 1.
No → Repa ir th e Gr oun d cir cuit for an open .
Per for m BODY VERIFICATION TE ST - VE R 1.
176
HEAT IN G & A/C
WATER CYCLE VALVE CON TROL HIGH OR OP EN (ACTIVE) — Co nt inued