TE S T ACTION AP PLICAB ILITY
4 Tur n th e ign it ion off.
Discon n ect t he In st r u m en t Clu st er C1 ha r n ess conn ect or.
Discon n ect t he Ambient Tem per a t u r e Sensor h a r n ess con n ect or.
Mea su r e t h e r esista n ce of t h e Am bien t Tem per a t u r e Sen sor Sign a l (+) cir cu it
bet ween th e In st r u m en t Clu st er C1 h a r n ess con n ect or an d th e Ambien t Tem per a t u r e
Sen sor ha r n ess con n ect or.
Is t h e resista n ce a bove 10 ohm s?
All
Ye s → Repa ir th e Ambien t Tem per a t u r e Sen sor Sign a l (+) cir cu it for a n
open .
Per for m BODY VERIFICATION TE ST - VE R 1.
No → Repla ce t h e In str u m en t Clu st er in a ccor da n ce wit h t h e Ser vice
In for m a t ion .
Per for m BODY VERIFICATION TE ST - VE R 1.
180
INSTRUMENT CLUSTER
AMB IEN T TEMP S ENS OR OP EN/S HORT TO BATTERY — Co nt in ued