7. 1. 2. 7 E-0020 Counter Error (E-020)
Cause Checking
order
Checking
Res
ult
Treatment
Service Mode 1 Has the setting of Adjustment Mode Item
No.753 set to “1”?
Yes Set it to “0”.
7. 1. 2. 8 E-0031 / 0032 / 0033 High Voltage Output Error
E-0031: Image Corona Output Error
E-0032: Separation Corona Output Error
E-0033: Transfer Corona Output Error
Cause Checking
order
Checking
Res
ult
Treatment
Wire 1 Are wires among Image Corona, HV
Power Supply PCB and PW11720 PCB
connected properly?
No Connect them properly.
2 (For Image Corona / Cleaning Roller
only)
Is the spring on the left bottom of the
Process Unit OK?
No Correct it properly.
Image Corona 3 Is the Image Corona dirty? Yes Clean each Corona Wire,
Grid Plate and housing.
Is the Corona Wire broken? Yes Replace the Corona Wire.
Cleaning Roller 4 Does the bias terminal plate touch to
Cleaning Roller shaft properly?
No Remove and reapply
conductive grease to
Cleaning Roller shaft.
Relocate the bias terminal
plates properly.
Is grease applied enough? No Remove and reapply
conductive grease to
Cleaning Roller shaft.
Transfer Corona 5 Is the Transfer Corona dirty? Yes Clean each Corona Wire
and housing.
Is the Corona Wire broken? Yes Replace the Corona Wire.
Separation Corona 6 Is the Separation Corona dirty? Yes Clean each Corona Wire
and housing.
Is the Corona Wire broken? Yes Replace the Corona Wire.
HV Power Supply 7 Can you fix the problem if you replace
the HV Power Supply?
Yes OK