751 Disable HV Error Detection Mode
“Disable HV Error Detection Mode” functions just as Error Mask Mode for high voltage errors.
This allows the system to ignore service call errors regarding high voltage power supply (E-0031,
E-0032, E-0033, E-0034) and prevents the concerning error code from being displayed both on the
sub UI and the touch screen.
“Disable HV Error Detection Mode” ON is not canceled by turning off the machine, but remains
until set to OFF manually.
Setting value Contents
0 HV error detection works normally.
1 The system ignores any HV Error.
753 Counter Setting
Setting value Contents
0 Keep the value unchanged.
1 Never use.
754 Total Increment of Developer Bias Adjustment
This item only shows the conversion value of the current analog output for Developer Bias.
Setting Range
000 to 9FE
NOTE
TAKE GREAT CARE. The system ignores high voltage errors caused by ANY REASON
while “Disable HV Error Detection Mode” is ON.
It is recommended that “Disable HV Error Detection Mode” remains OFF in the usual usage.
NOTE
This setting does not function. Keep the value unchanged from “0”.
NOTE
This setting has been factory-adjusted. Keep the value unchanged.