K117sm8e7
8-77
768 Motor Setting
Setting value Contents
0 Keep the value unchanged.
1 Never use.
769 Wait Time of Media Feed Start
The start timing of media feeding from the Roll Deck can be adjustable. This is used just in case a
horizontal, weak, black line appears on a print in 10mm of the leading edge.
Decreasing the setting value will delay the start timing to feed roll media.
Setting Range Step of increment
0 to 60 100 milliseconds
770, 771 Additional Toner Supply Time
These items specify the period of operation time of Toner Supply Motor. These are applied only to
the User’s “additional” Toner Supply Command on the UI screen.
Item
No.
Setting Item Default
Value
Setting
range
Step of
increment
770 Additional Toner Supply Time
(toner supply motor ON)
9 1 to 30 min
771 Additional Toner Toner Supply Time
(Agitation only)
1 1 to 30 min
NOTE
Toner Supply time for “initial toner setup” is fixed in 10 minutes and is not adjustable.
NOTE
This setting does not function. Keep the value unchanged.