EasyManua.ls Logo

KIP 700m - 653 Target Density; 654 Toner Patch Adjustment; 655 Density Measure Interval

KIP 700m
679 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
K117sm8e7
8-71
653 Target Density
It is possible to change Target Density that should be achieved and maintained for consistent print
density.
If the current density does not meet Target Density, Regulation (Developer) Bias will be
automatically adjusted based on the current Adjustment Level.
If the current Density Value is judged “not enough” (lighter than required), the next level will be
applied.
If the current Density Value is judged “adequate”, the current level remains.
There is possibility for the Density Value to be judged “too much enough” (darker than
required), then the previous level will be applied.
If you increase the setting value by “+1”, Target Density will rise and thus Auto Adjustment Level
would be switched to the next level earlier.
Setting Range
000 to 400
654 Toner Patch Adjustment
Setting Range
0 to 16
655 Density Measure Interval
It is possible to change an interval of Density Measure.
When Bias 3 Time in Information Mode reaches a specified period in this setting, Density Measure
will run.
If you increase the setting value by “+1”, the interval of Density Measure becomes 1 hour longer.
Setting Range Step of increment
1 to 18 1 hour
NOTE
This setting has been factory-adjusted. Keep the value unchanged.
NOTE
This setting has been factory-adjusted. Keep the value unchanged.
NOTE
This setting has been factory-adjusted. Keep the value unchanged.