784, 785 Limit Temperature of LED Stitch Compensation
Under an extremely hot / cold emvironment, LED Blocks are compensated additionally.
No. 784, 785 work as a threshold of the temperature for that.
Item
No.
Setting Item Setting
range
784 Upper Limint Temperature of LED Stitch Compensation 30 to 50
785 Lower Limint Temperature of LED Stitch Compensation 10 to 20
787 Transfer Corona ON Timing Compensation (Paper Tray)
It is possible to adjust the timing that the Transfer Corona starts discharging during the print cycle.
If you increase the setting value by “+1”, the timing to start discharging is 1ms delayed.
Setting Range Step of increment
1 to 999 1millisecond
NOTE
This setting has been factory-adjusted. Keep the value unchanged.
NOTE
You may lose some leading image as the following example if you increase the setting value
too much, because the timing to start discharging is too much delayed.
Normal Setting value is increased too much.
Transfer Corona starts
discharging at this point.