K117sm8e7
8-88
801 to 812 Separation Corona OFF Timing (Roll)
It is possible to adjust the timing that the Separation Corona stops discharging during the print
cycle. This can be configured by every media type / width.
If you increase the setting value by “+1”, the timing to stop discharging is 1mm delayed.
Setting Range Step of increment
0 to 100 1mm
Plain
Paper
Tracing
Paper
Film
A3, 11”, 12” No.801 No.802 No.803
A2, 15”, 17”, 18” No.804 No.805 No.806
A1, 22”, 24” No.807 No.808 No.809
A0, B1, 30”, 34”, 36” No.810 No.811 No.812
813 Encoder Type
No.813 specifies the type of the pulse generator wheel on “Feed Encoder” (PH4, PENC_S).
Setting Range
0 to 1
NOTE
This setting has been factory-adjusted. Keep the value unchanged.
An incorrect setting would cause improper cut length.