8-57
045 Fuser Temperature to start idling
It is possible to decide the temperature to start idling.
When the Fuser Temperature reaches the value specified in this No.045 during the warming up,
the Fuser Motor starts rotating to drive the Fuser Roller (idling).
Setting Range Step of increment
100 to 140 1
o
C
Setting value of 625 to 648
(Example : 160
o
C)
(
o
C)
Setting value of 045
(Example: 140
o
C)
0 (Time)
Ready (Idling stops.)
Turn on Idling starts.
046 Warm Sleep – Fuser Temperature
It is possible to decide the temperature which is maintained in the Warm Sleep.
Setting Range Step of increment
100 to 160 1
o
C
Setting value of 625 to 648
(Example: 160
o
C)
(
o
C)
Setting value of 046
(Example: 100
o
C)
0
(Time)
Warm Sleep starts.
100
o
C is maintained after this point.