K117sm8e7
8-69
637 to 642 Print - Fuser Temperature (24”/22”/A1)
It is possible to adjust the Fuser Temperature for 24”/22”/A1 wide media in the print cycle.
You can specify the temperature for each type and size of media separately.
The Fuser Temperature becomes 1 degree higher if you increase the setting value by “+1”.
Item No. Setting Item Setting
range
Step of
increment
637 Print - Fuser Temperature
(Plain) (24” / 22” / A1)
120 to 180 1
o
C
638 Print - Fuser Temperature
(Tracing) (24” / 22” / A1)
120 to 180 1
o
C
639 Print - Fuser Temperature
(Film) (24” / 22” / A1)
120 to 180 1
o
C
640 Print - Fuser Temperature
(Special / Plain) (24” / 22” / A1)
120 to 180 1
o
C
641 Print - Fuser Temperature
(Special / Tracing) (24” / 22” / A1)
120 to 180 1
o
C
642 Print - Fuser Temperature
(Special / Film) (24” / 22” / A1)
120 to 180 1
o
C
643 to 648 Print - Fuser Temperature (36”/34”/30”/A0/B1)
It is possible to adjust the Fuser Temperature for 36”/34”/30”/A0/B1 wide media in the print cycle.
You can specify the temperature for each type and size of media separately.
The Fuser Temperature becomes 1 degree higher if you increase the setting value by “+1”.
Item No. Setting Item Setting
range
Step of
increment
643 Print - Fuser Temperature
(Plain) (36” / 34” / 30” / A0 / B1)
120 to 180 1
o
C
644 Print - Fuser Temperature
(Tracing) (36” / 34” / 30” / A0 / B1)
120 to 180 1
o
C
645 Print - Fuser Temperature
(Film) (36” / 34” / 30” / A0 / B1)
120 to 180 1
o
C
646 Print - Fuser Temperature
(Special / Plain) (36” / 34” / 30” / A0 / B1)
120 to 180 1
o
C
647 Print - Fuser Temperature
(Special / Tracing) (36” / 34” / 30” / A0 / B1)
120 to 180 1
o
C
648 Print - Fuser Temperature
(Special / Film) (36” / 34” / 30” / A0 / B1)
120 to 180 1
o
C
649 Density Sensor Output Monitor
It is possible to change the mode to monitor the default analog output of Density Sensor.
Setting Range
2 to 9
NOTE
This setting is factory-use only. Keep the value unchanged.