K117sm8e6
8-59
050 Reaction Time of Toner Supply Motor
It is possible to change the reaction time of Toner Supply Motor.
“Reaction time” is the time taken until the Toner Supply Motor starts working since “Toner Low”
has been detected.
The reaction time becomes 1 second longer if you increase the setting value by “+1”.
Setting Range Step of increment
1 to 30 1 second
Toner Low Motor starts working Motor stops
(Time)
Setting value of No.050
051 Toner Supply Motor ON Time
It is possible change the time the Toner Supply Motor works (ON time).
The ON time becomes 1 second longer if you increase the setting value.
Setting Range Step of increment
1 to 75 1 second
Toner Low Motor starts working Motor stops
(Time)
Setting value of No.051
NOTE
The reaction time may be too long if the image gets lighter and lighter when you make large
volume prints continuously.
In this case try to decrease the setting value of No.050 to shorten the reaction time.
NOTE
The ON time may be too short if the image gets lighter and lighter when you make large
volume prints continuously.
In this case try to increase the setting value of No.051 to make the ON time longer.