12 Correction Time
BUD No.12 is a reserved parameter for “white level compensation”.
13 Switching Step1
BUD No.13 is a speed setting of the feed roller’s eccentricity compensation.
setting range
0x0000 to 0xFFFF
14 Switching Step2
BUD No.14 is a speed setting of the feed roller’s eccentricity compensation.
setting range
0x0000 to 0xFFFF
Reference
Shading defines the “black level” / “white level” for each pixel.
Shading also averages the reading level (black level / white level) for the pixels on each CIS
image block borders. This is to diminish visual density gap at the borders.
BUD has several “fixed” or “factory adjusted” items for auto adjustments such as No.12.
A setting change on them may malfunction the auto adjustments as intended.
NOTE
Fixed value. Keep the value unchanged.
NOTE
Factory adjusted. Keep the value unchanged.
NOTE
Factory adjusted. Keep the value unchanged.