K117sm8e7
8-75
755 Developer Bias Increment for Adjustment Level 1 and after
It is possible to change the amount (increment) of Developer Bias Adjustment.
A specified increment of Developer Bias will be applied at switching to and as of Auto Adjustment
Level 1.
The default voltage value of the increment is approximately 50V (corresponding to “80” in the
setting value) for switching to Auto Adjustment Level 1. The increased Developer Bias will be
applied to the subsequent Auto Adjustment Level.
If you increase the setting value by “+1”, the increment of Developer Bias Adjustment becomes
higher.
Setting Range Step of increment
0 to 800 0.5V
756, 757 Developer Bias Limit
These items specify the minimum / maximum Developer Bias.
Item
No.
Setting Item Setting
range
755 Developer Bias Limit (minimum, absolute value) 000 to 9FE
756 Developer Bias Limit (maximum, absolute value) 000 to 9FE
758 Total Increment of Regulation Bias Adjustment
This item only shows the conversion value of the current analog output for Regulation Bias.
Setting Range
0 to 340
NOTE
This setting has been factory-adjusted. Keep the value unchanged.
NOTE
This setting has been factory-adjusted. Keep the value unchanged.
NOTE
This setting has been factory-adjusted. Keep the value unchanged.