5 ED Gamma Select
BUD No.5 is a mode selector of which “Error Diffusion Gamma” table to be used.
This is to be decided by your system configuration. Choose the correct combination.
setting value Contents
0
1
2
3 Default
4
6 Sleep Time
BUD No.6 is a timer setting for the scanner to run sleep mode. (Auto Power OFF)
The period of inactivity can be specified. The setting value “0” means Auto Power OFF disabled.
setting range step of increment
0 to 60 1 minute
9 Doc. Entry Time
BUD No.9 is a timer setting for the scanner to catch an inserted original.
Decreasing the value takes longer time to catch the original’s leading edge.
setting range step of increment
5 to 50 0.1 second
10 ISO/ANSI
BUD No.10 is a table selector of the original width definition.
The definition is usually specified by the scan software.
setting range
0 to 3
11 Doc. Entry Speed
BUD No.11 is a speed selector to catch an inserted original.
Increasing the value moves the original to the standby position slower.
setting range
0 to 9 0: fastest
9: slowest