StapleSmart finisher software error service check
Action Yes No
Step 1
Turn o the machine, and then turn it back on.
Does the problem remain?
Go to step 2. The problem is
solved.
Step 2
Replace the StapleSmart finisher.
Does the problem remain?
Contact the next
level of support.
The problem is
solved.
Motor (StapleSmart finisher transport) service check
Action Yes No
Step 1
Check all connections on the output option controller card, and if
necessary, replace the connections.
Does the problem remain?
Go to step 2. The problem is
solved.
Step 2
Replace the StapleSmart finisher.
Does the problem remain?
Contact the next
level of support.
The problem is
solved.
Motor (StapleSmart finisher eject) service check
Action Yes No
Step 1
Check all connections on the output option controller card, and if
necessary, replace the connections.
Does the problem remain?
Go to step 2. The problem is
solved.
Step 2
Replace the StapleSmart finisher.
Does the problem remain?
Contact the next
level of support.
The problem is
solved.
7462
Diagnostic information
154