Diagnostic information 2-145
7558-xxx
Go Back
Previous
Next
3
Check the sensor (ADF
registration) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch ADF/SCANNER
SENSOR TESTS.
4. Touch Sensor (ADF
registration).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Go to step 5. Go to step 4.
4
Check the sensor (ADF
registration) for proper
connection.
Is the above component
properly connected?
Replace the sensor (ADF
registration). Go to Sensor
(ADF registration) removal” on
page 4-247.
Replace the connections.
5
Check the sensor (ADF inverter)
for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch ADF/SCANNER
SENSOR TESTS.
4. Touch Sensor (ADF
inverter).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Go to step 7. Go to step 6.
6
Check the sensor (ADF inverter)
for proper connection.
Is the above component
properly connected?
Replace the sensor (ADF
inverter). Go to “Sensor (ADF
inverter) removal” on
page 4-244.
Replace connections.
7
Check the ADF feed motor for
proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch ADF/SCANNER
MOTOR TESTS.
4. Touch ADF registration
motor.
Does the above component
operate properly?
Go to step 9. Go to step 8.
Step Action and questions Yes No

Table of Contents

Related product manuals