2-178 Service Manual
7558-xxx
3
Check the eject shaft roller motor
assembly for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Media eject motor
(forward).
5. Touch Media eject motor
(reverse).
Does the above component
operate properly?
Go to step 5. Go to step 4.
4
Check the eject shaft roll motor
for proper connection.
Is the above component
properly connected?
Replace the eject shaft roll motor.
Go to “Media eject motor
assembly removal” on
page 4-369.
Replace the connection.
5
Check the media eject clamp
clutch for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Media eject clutch.
Does the above component
make an audible clicking
noise?
Go to step 7. Go to step 6.
6
Check the media eject clamp
clutch for proper connection.
Is the above component
properly connected?
Replace the media eject clamp
clutch. Go to “Media eject clamp
clutch removal” on page 4-368.
Replace the connection.
7
Perform a POR.
Does the error continue when
the power is turned off/on?
Replace the finisher controller
PCBA. Go to “Finisher PCBA
removal” on page 4-353.
Problem resolved
Step Action and questions Yes No