Diagnostic information 2-221
7558-xxx
Go Back
Previous
Next
2
Check the sensor (buffer path)
for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch FINISHER SENSOR
TESTS.
4. Touch Sensor (buffer path).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Go to Step 4. Go to Step 3.
3
Check the sensor (buffer path) for
proper connection.
Is the above component
properly connected?
Replace the sensor (buffer path).
Go to “Sensor (buffer path)
removal” on page 4-389.
Replace connections.
4
Check the entrance/paddle motor
for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Entrance/paddle
motor.
Does the above component
operate properly?
Go to step 6. Go to step 5.
5
Check the entrance/paddle motor
for proper connection.
Is the above component
properly connected?
Replace the entrance/paddle
motor.
Go to Stepper motor
(entrance/paddle) and belt
(entrance/paddle) removal” on
page 4-416.
Replace connections.
6
Check the exit stepper motor for
proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Exit motor.
Does the above component
operate properly?
Go to step 8. Go to step 7.
Step Action and questions Yes No