Diagnostic information 2-231
7558-xxx
Go Back
Previous
Next
3
Check the clamp drive motor for
proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Media eject clamp
motor (clamp).
5. Touch Media eject clamp
motor (unclamp).
Does the above component
operate properly?
Go to step 5. Go to step 4.
4
Check the clamp drive motor for
proper connection.
Is the above component
properly connected?
Replace the clamp drive motor.
Go to Clamp drive motor
removal” on page 4-340.
Replace the connection.
5
Check the eject shaft roll motor
for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Media eject motor
(forward).
5. Touch Media eject motor
(reverse).
Does the above component
operate properly?
Go to step 7. Go to step 6.
6
Check the eject shaft roll motor
for proper connection.
Is the above component
properly connected?
Replace the eject shaft roll motor.
Go to “Media eject motor
assembly removal” on
page 4-369.
Replace the connection.
Step Action and questions Yes No