2-234 Service Manual
7558-xxx
Go Back
Previous
Next
4
Check the booklet entrance
motor for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Booklet entrance
motor.
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Go to Step 6. Go to Step 5.
5
Check the booklet entrance
motor for proper connection.
Is the above component
properly connected?
Replace the booklet entrance
motor.
Go to “Booklet media entrance
drive motor removal” on
page 4-329.
Replace connections.
6
Check the booklet controller card
assembly for proper connection.
Is the above component
properly connected?
Replace the booklet controller
card assembly).
Go to “Booklet controller card
assembly removal” on
page 4-322.
If the error remains, then go to
step 7.
Replace connections.
7
Check the finisher controller
PCBA for proper connection.
Is the above component
properly connected?
Go to Step 8. Replace the connections.
8
POR the machine.
Does the error continue?
Replace the finisher controller
PCBA.
Go to “Finisher PCBA removal
on page 4-353.
Problem resolved
Step Action and questions Yes No