215916 411 Revision A
5.12 Every 1000 Hours
Complete the following maintenance tasks every 1000 hours of operation:
• Change fuel tank vent filter. For instructions, refer to 5.12.1 Removing and Installing Fuel Tank Vent Filter, page 411.
• Clean DEF supply module filter. For instructions, refer to 5.12.2 Diesel Exhaust Fluid Supply Module Filter, page 413.
• Change wheel drive lubricant. For instructions, refer to 5.6.7 Changing Wheel Drive Lubricant – 10 Bolt, page 365.
5.12.1 Removing and Installing Fuel Tank Vent Filter
The fuel tank is vented by a hose and filter in the platform rail. Change the filter every 1000 hours or annually, whichever
occurs first.
Change the filter as follows:
DANGER
To prevent bodily injury or death from the unexpected startup of the machine, always stop the engine and remove the
key from the ignition before leaving the operator’s seat for any reason.
WARNING
To avoid personal injury or death from explosion or fire, do NOT smoke or allow flame or sparks near windrower when
servicing.
1. Shut down the engine, and remove the key from the ignition.
Figure 5.122: Right Service Platform
2. Remove two bolts (A) and plate (B) on the right service
platform.