EasyManua.ls Logo

MacDon M1240 - Page 552

MacDon M1240
614 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
215916 532 Revision A
Fault Codes
Telltale
Short
Description
Full Fault
Description
Recommended
Fix/Check Message
SA SPN FMI
176 521151
4
Electrical
System
Brake Lights, Eng Fwd EK7 Relay Normally Closed
contact is open
Check roof relay module
176 521151
5
Electrical
System
Brake Lights, Eng Fwd EK7 Relay coil is not
receiving power
Check wiring to roof relay module EK7. Contact dealer.
176 521151 6
Electrical
System
Brake Lights, Eng Fwd EK7 Relay Normally open
contact is shorted
Check roof relay module
176 521151
7
Electrical
System
Brake Lights, Eng Fwd EK7 Relay Normally closed
contact is shorted
Check roof relay module
176 521159
1
Electrical
System
Rear Swath Lights EK8 Relay coil open or not
present
Check roof relay module
176 521159 2
Electrical
System
Rear Swath Lights EK8 Relay Coil shorted or
failed relay driver
Check roof relay module
176 521159 3
Electrical
System
Rear Swath Lights EK8 Relay Normally Open
contact is open
Check roof relay module
176 521159
4
Electrical
System
Rear Swath Lights EK8 Relay Normally Closed
contact is open
Check roof relay module
176 521159
5
Electrical
System
Rear Swath Lights EK8 Relay coil is not
receiving power
Check wiring to roof relay module EK8. Contact dealer.
176 521159 6
Electrical
System
Rear Swath Lights EK8 Relay Normally open
contact is shorted
Check roof relay module
176 521159
7
Electrical
System
Rear Swath Lights EK8 Relay Normally closed
contact is shorted
Check roof relay module
176 521167
1
Electrical
System
Beacon Lights EK9 Relay coil open or not
present
Check roof relay module
176 521167 2
Electrical
System
Beacon Lights EK9 Relay Coil shorted or
failed relay driver
Check roof relay module
176 521167 3
Electrical
System
Beacon Lights EK9 Relay Normally Open
contact is open
Check roof relay module
176
521167
4
Electrical
System
Beacon Lights EK9 Relay Normally Closed
contact is open
Check roof relay module
176 521167
5
Electrical
System
Beacon Lights EK9 Relay coil is not
receiving power
Check wiring to roof relay module EK9. Contact dealer.
176 521167 6
Electrical
System
Beacon Lights EK9 Relay Normally open
contact is shorted
Check roof relay module