ND-70348 (E) CHAPTER 4
Page 203-1
Revision 5.0
ASYDL
SYS-
TEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
512-1535
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
527
b
0
~ b
3
Designate the number of the tandem node for Netfusing tandem connec-
tion.
b
4
DP (Dial Pulse) relay broadcasting to Netfusing Link
0/1 = Invalid/Valid
0
b
5
Speech Link Reconnection via FCCS
over IP network.
0/1 = Valid/Invalid
b
6
TCP connection status monitor
0/1 = Valid/Invalid
Note :
When SP-3549 IPTRK-B is used as the main firm, and SP-3548
IPTB·SUB PROG-A as the sub firm, assign this data to “1”.
(Since Release 9 software.)
0
b
7
Not used
Example :
A
123
CB
A to B: 2 (two) tandem nodes
A to C: 3 (three) tandem nodes
FCCS

Table of Contents