−−−−−<SYS MODE>−−−−−−
DENSITY INPUT
TYPE
PULSE INPUT
1:NONE
2:PULSE INPUT
−−−−−−<SELECT>−−−−−−−
|CAN−| |
EXIT| CEL| |ENTR
−−−−−<SYS MODE>−−−−−−
DENSITY INPUT
・TYPE
PULSE INPUT
−−−−−<SUB MENU>−−−−−
MAIN| | |
MENU| | |ENTR
E-880TM-3-E
1
7.4.6 Density Input Setup (DENSITY INPUT)
The type of input for the density input is set up here.
(1)Density input submenu screen
At the submenu, move the cursor to the desire setup item with the up and down arrow keys.
At the touch of function key “ENTR”, the screen switches to the desired setup screen.
① Density input type setup (TYPE) on page 156
Densitye input submenu screen p. 156
To the setup screen pointed by the cursor
7.1.1 SYS mode main menu screen p. 142
① Density input type setup (TYPE)
The type of input for the density input is set up here.
※1
On EL4301, ② Density calculation costant (CONSTANT) p. 105
On EL4311, ② Density calculation costant (CONSTANT) p. 114
On EL4321, ② Density calculation costant (CONSTANT) p. 126
←Input type option setup
For details of option setup, see “(2) Option select setup screen (SELECT)” on
page 46.
※ In cases where the user has changed the input type to NONE (constant) or
to other type, do not fail to set up the constant (※1) at the density input
setup in the SET mode, and set up the pulse output scaling (Section
6.4.27 Pulse output scaling setup (PULSE OUT DIVIDE) on page 138).
Unless they are so configured, the computer possibly may not perform
properly.