Oval EL4101 - EL4501 Multipoint Temperature Compensated Flow Computer

Oval EL4101
206 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...

 
⇒Instantflowratestup(FLOWRATESETTING)p.67
 
 
・UNIT(unitset)


*TEMP.INPUT(temperatureinputset)
⇒Temperatureinputsetup(TEMP.INPUT)p.48
・UNIT(unitset)
・CONSTANT(constant)
・BASESCALE(baselineset)
・FULLSCALE(fullscaleset)
・UNDERALARMPOINT(underalarmpointset)
・OVERALARMPOINT(overalarmpointset)
・UNDERFALLBACK(underfallbacklevelset)
・OVERFALLBACK(overfallbacklevelset)
・SMOOTHJINGCOEF.(smoothingfactorset)
*PULSEINPUT(pulseinputset)
⇒Pulseinput(PULSEINPUT)p.66
・METERFACTOR(meterfactorset)
・MAX.FREQUENCY(max.frequencyset)
*FLOWRATESETTING(instantflowrateset)
・MEASURE.TYPE(measurementtypeset)
・LOW‒CUTFRQ.(lowcutofffrequencyset)
・COUNTSTOP(totalizingstopset)
・SMOOTHINGCOEF.(smoothingfactorset)
・MAX.PERIOD(max.periodset)
・MEASURE.NUMBER(numberofmeas.cyclesset)
・INTERPOLATION(interpolationset)
・REF.OSCILLATOR(ref.oscillatorcorrectionset)
*TOTALCOUNT(Q)(totalcount(Q)set)
⇒Totalcountsetup(TOTALCOUNT)p.74
・UNIT(unitset)
*TOTALCOUNT(Qμf)(totalcount(Qμf))set)
・UNIT(unitset)
⇒Totalcountsetup(TOTALCOUNT)p.74
⇒Totalcountsetup(TOTALCOUNT)p.74
*TOTALCOUNT(Qμfρ(totalcount(Qμfρ))set)
*ANALOGOUTPUT(analogoutputset)
⇒Analogoutputsetup(ANALOGOUTPUT)p.76
・UNIT(unitset)
・BASESCALE(baselineset)
・FULLSCALE(fullscaleset)
・HIGHLIMIT(mA)(outputhighlimitset)
・LOWLIMIT(mA)(outputlowlimitset)
・SMOOTHINGCOEF.(smoothingfactorset)
*3αCOMPEN.(3αcompensateset)
⇒3αcompenstatesetup(3αCOMPEN.)p.80
・TYPE(typeset)
・ALFA(α)(αset)
・BETA(β)(βset)
・REF.TEMP.(ref.temp.set)
*DENSITYPARAMETER(dens.paramset)
⇒Dens.param.setup(DENSITYPARAM),EL4301p.130
・UNIT(unitset)
・UNDERALARMPOINT(underalarmpointset)
・OVERALARMPOINT(overalarmpointset)
*VISCOSITYCOMPEN.(viscositycorrectionfactorset)
⇒Viscositycorrrection(μ)setup(VISCOSITYCOMP.(μ))p.134
・UNIT(unitset)
・UNDERALARMPOINT(underalarmpointset)
・OVERALARMPOINT(overalarmpointset)
・μ1(viscositycorrectedformetererrorμ1)
・μ2(viscositycorrectedformetererrorμ2)
・μ3(viscositycorrectedformetererrorμ3)
・FREQUENCY1(flowvelocityatmetercalibration(frequency1))
・METERERROR11(metererror)
・METERERROR12(metererror)
・METERERROR13(metererror)
・FREQUENCY2(flowvelocityatmetercalibration(frequency2))
・METERERROR21(metererror)
・METERERROR22(metererror)
・METERERROR23(metererror)
・FREQUENCY3(flowvelocityatmetercalibration(frequency3))
・METERERROR31(metererror)
・METERERROR32(metererror)
・METERERROR33(metererror)
・FREQUENCY4(flowvelocityatmetercalibration(frequency4))
・METERERROR41(metererror)
・METERERROR42(metererror)
・METERERROR43(metererror)
   E-880TM-3-E
01
 11.11 EL4501 Multipoint Temperature Compensated Flow Computer
SET mode