DENSITY 1/2
257.620
g/ml
DENSITY(C)
800.0000
g/ml
MODE|ERR.|PAGE|
MENU|LOG.| UP|
/
TEMPERATURE 2/2
0.00
C
DENSITY PERIOD
99999.9
μs
%MASS 3/3
4.74
%
MODE|ERR.|PAGE|PAGE
MENU|LOG.| UP|DOWN
/
TOTAL COUNT 1/3
123
l
TOTAL COUNT(C)
123
kg
MODE|ERR.|PAGE|
MENU|LOG.| UP|
/
FLOW RATE 2/3
0
l/h
FLOW RATE(C)
0
kg/h
TEMPERATURE
0.00
C
MODE|ERR.|PAGE|PAGE
MENU|LOG.| UP|DOWN
/
METER ERROR 3/3
1.00000
TEMP. COMPEN.
1.00000
DENSITY
1000.0
kg/l
MODE|ERR.| |PAGE
MENU|LOG.| |DOWN
E-880TM-3-E
30
5.4.6 EL4211 Liquid Temperature Compensated Flow Computer (conversion into mass)
5.4.7 EL4301 Density Computer for Mass Flowmeter
←RUN mode screen 1
Pressing function key “PAGE UP” switches the screen to the next screen.
“TOTAL COUNT”: Uncorrected total flow
“TOTAL COUNT (C)”: Corrected total mass flow
※ Measurement units, exponent, and indicated values vary with actual
settings (SET mode).
←RUN mode screen 2
Pressing function key “PAGE UP” switches the screen to the next screen;
pressing function key “PAGE DOWN” switches the screen to the previous screen.
“FLOW RATE”: Uncorrected instant flowrate
“FLOWRATE (C)”: Corrected instant mass flowrate
“TEMPERATURE”: Temperature
※ The placement of decimal point in temperature reading varies with the
measurement unit selected. (For the decimal point of temperature, see
“① Temperature input unit setup (UNIT)” on page 51.)
←RUN mode screen 3
Pressing function key ”PAGE DOWN” switches the screen to the previous
screen.
“METER ERROR”: Meter error correction factor
“TEMP. COMPEN.”: Temperature correction factor
“DENSITY”: Density
※ The placement of decimal point in density reading varies with the
measurement unit selected. (For the decimal point of density, see
“① Density unit setup (UNIT)” on page 100.)
←RUN mode screen 2
Pressing function key “PAGE UP” switches the screen to the next screen;
pressing function key “PAGE DOWN” switches the screen to the previous screen.
“TEMPERATURE”: Temperature
“DENSITY PERIOD”: Density period
“%MASS”: Solids content weight concentration
※ The placement of decimal point in temperature or density period reading
varies with the measurement unit selected. (For the decimal point of
temperature, see “① Temperature input unit setup (UNIT)” on page 51.
For the decimal point of density period, see “① Density pulse input unit
setup (UNIT)” on page 72.)
←RUN mode screen 1
Pressing function key “PAGE UP” switches the screen to the next screen.
“DENSITY”: Density
“DENSITY (C)”: Density (corrected)
※ Measurement units, exponent, and indicated values vary with actual
settings (SET mode).
※ The placement of decimal point in uncorrected and corrected density
readings varies with the measurement units selected. (For the decimal
point of uncorrected and corrected density, see “① Density calculation
unit setup (UNIT)” on page 105.)