5.4.6 EL4211 Liquid Temperature Compensated Flow Computer (conversion into mass)
5.4.7 EL4301 Density Computer for Mass Flowmeter
RUN mode screen 1
Pressing function key PAGE UP switches the screen to the next screen.
TOTAL COUNT: Uncorrected total flow
TOTAL COUNT (C): Corrected total mass flow
Measurement units, exponent, and indicated values vary with actual
settings (SET mode).
RUN mode screen 2
Pressing function key PAGE UP switches the screen to the next screen;
pressing function key PAGE DOWN switches the screen to the previous screen.
FLOW RATE: Uncorrected instant flowrate
FLOWRATE (C): Corrected instant mass flowrate
TEMPERATURE: Temperature
The placement of decimal point in temperature reading varies with the
measurement unit selected. (For the decimal point of temperature, see
Temperature input unit setup (UNIT)” on page 51.)
RUN mode screen 3
Pressing function key PAGE DOWN switches the screen to the previous
screen.
METER ERROR: Meter error correction factor
TEMP. COMPEN.: Temperature correction factor
DENSITY: Density
The placement of decimal point in density reading varies with the
measurement unit selected. (For the decimal point of density, see
Density unit setup (UNIT)” on page 100.)
RUN mode screen 2
Pressing function key PAGE UP switches the screen to the next screen;
pressing function key PAGE DOWN switches the screen to the previous screen.
TEMPERATURE: Temperature
DENSITY PERIOD: Density period
%MASS: Solids content weight concentration
The placement of decimal point in temperature or density period reading
varies with the measurement unit selected. (For the decimal point of
temperature, see “ Temperature input unit setup (UNIT)” on page 51.
For the decimal point of density period, see Density pulse input unit
setup (UNIT)” on page 72.)
RUN mode screen 1
Pressing function key PAGE UP switches the screen to the next screen.
DENSITY: Density
DENSITY (C): Density (corrected)
Measurement units, exponent, and indicated values vary with actual
settings (SET mode).
The placement of decimal point in uncorrected and corrected density
readings varies with the measurement units selected. (For the decimal
point of uncorrected and corrected density, see Density calculation
unit setup (UNIT)” on page 105.)