Remote Control Commands
R&S
®
SMW200A
1065User Manual 1175.6632.02 ─ 30
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OBASeband:TDELay <ObasTimeDelay>
Specifies the trigger delay for triggering by the signal from the other path.
Maximum trigger delay and trigger inhibit values depend on the installed options. See
"Specifying delay and inhibit values" on page 242.
Parameters:
<ObasTimeDelay> float
Range: 0 to depends on the symbol rate
Increment: 0.25E-9
*RST: 0
Default unit: s
Example: See Example "Specifying delay and inhibit values in time units"
on page 1022
Manual operation: See "(Specified) External Delay/(Specified) Trigger Delay"
on page 255
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OBASeband:INHibit
<Inhibit>
For triggering via the other path, specifies the number of samples by which a restart is
inhibited.
Parameters:
<Inhibit> integer
Range: 0 to 67108863
*RST: 0
Default unit: sample
Example: See Example "Managing waveform files" on page 1020
Manual operation: See "External / Trigger Inhibit" on page 255
[:SOURce<hw>]:BB:ARBitrary:TRIGger:DELay:UNIT <TrigDelUnit>
Sets the units the trigger delay is expressed in.
Parameters:
<TrigDelUnit> SAMPle | TIME
*RST: SAMPle
Example: See Example "Specifying delay and inhibit values in time units"
on page 1022
Manual operation: See "(External) Delay Unit" on page 255
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal]:DELay <Delay>
Specifies the trigger delay in samples.
SOURce Subsystem