Remote Control Commands
R&S
®
SMW200A
1064User Manual 1175.6632.02 ─ 30
[:SOURce<hw>]:BB:ARBitrary:TRIGger:EXECute
Executes an internal trigger event.
Example: See Example "Managing waveform files" on page 1020
Usage: Event
Manual operation: See "Execute Trigger" on page 254
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal]:SYNChronize:OUTPut
<Output>
Enables signal output synchronous to the trigger event.
Parameters:
<Output> 0 | 1 | OFF | ON
*RST: 1
Example: See Example "Managing waveform files" on page 1020
Manual operation: See "Sync. Output to External Trigger/Sync. Output to Trigger"
on page 254
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OBASeband:DELay <Delay>
Delays the trigger event compared to the trigger event in the other basebands.
Parameters:
<Delay> float
Range: 0 to 2147483647
Increment: 0.01
*RST: 0
Manual operation: See "(Specified) External Delay/(Specified) Trigger Delay"
on page 255
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OBASeband:RDELay?
Queries the time a trigger event form the other path is delayed.
Return values:
<ResTimeDelaySec> float
Range: 0 to 688
Increment: 0.25E-9
*RST: 0
Default unit: s
Example: See Example "Specifying delay and inhibit values in time units"
on page 1022
Usage: Query only
Manual operation: See "Actual Trigger Delay/Actual External Delay" on page 256
SOURce Subsystem