EasyManua.ls Logo

Rohde & Schwarz R&S SMW200A - Page 254

Rohde & Schwarz R&S SMW200A
1403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring the Internal Baseband Source
R&S
®
SMW200A
254User Manual 1175.6632.02 ─ 30
Remote command:
[:SOURce<hw>]:BB:DM:TRIGger:ARM:EXECute on page 1006
[:SOURce<hw>]:BB:ARBitrary:TRIGger:ARM:EXECute on page 1063
[:SOURce<hw>]:BB:MCCW:TRIGger:ARM:EXECute on page 1082
Execute Trigger
For internal trigger source, executes trigger manually.
Remote command:
[:SOURce<hw>]:BB:DM:TRIGger:EXECute on page 1006
[:SOURce<hw>]:BB:ARBitrary:TRIGger:EXECute on page 1064
[:SOURce<hw>]:BB:MCCW:TRIGger:EXECute on page 1082
Source
The following sources of the trigger signal are available:
"Internal"
The trigger event is executed manually by the "Execute Trigger".
"Internal (Baseband A/B)"
The trigger event is provided by the trigger signal from the other basebands.
If common trigger settings are applied, this trigger source is disabled.
"External Global Trigger"
The trigger event is the active edge of an external trigger signal provided and con-
figured at the USER x connectors.
"External Local Trigger"
The trigger event is the active edge of an external trigger signal provided and con-
figured at the local T/M/C connector.
With coupled trigger settings, the signal has to be provided at the T/M/C1/2/3 con-
nectors.
"External Local Clock"
The trigger event is the active edge of an external local clock signal provided and
configured at the local T/M/C connector.
With coupled trigger settings, the signal has to be provided at the T/M/C1 connec-
tor.
"Baseband Sync In"
Option: R&S SMW-B9
In primary-secondary instrument mode, secondary instruments are triggered by the
active edge of the synchronization signal.
"External Local Clock/Trigger" require R&S SMW-B10.
The polarity, the trigger threshold, and the input impedance of the input connectors can
be configured in the "Local and Global Connectors Settings" dialog.
See "Trigger Sources" on page 236.
See also Chapter 12.2, "Configuring Local and Global Connectors", on page 714.
Remote command:
[:SOURce<hw>]:BB:DM:TRIGger:SOURce on page 1004
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SOURce on page 1062
[:SOURce<hw>]:BB:MCCW:TRIGger:SOURce on page 1084
Sync. Output to External Trigger/Sync. Output to Trigger
Enables signal output synchronous to the trigger event.
Common Functions and Settings in the Baseband Domain

Table of Contents