Remote Control Commands
R&S
®
SMW200A
1068User Manual 1175.6632.02 ─ 30
*)
If R&S SMW-B9 is installed, the minimum marker duration depends on the sample/
symbol rate.
See "Marker Minimum Duration" on page 234.
Parameters:
<OffTime> integer
Range: 1 (R&S SMW-B10) / 1* (R&S SMW-B9) to
14913079
*RST: 1
Example: see Example "Managing waveform files" on page 1020
Manual operation: See "Marker Mode" on page 311
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:PATTern <Pattern>,
<BitCount>
Defines the bit pattern used to generate the marker signal.
Parameters:
<Pattern> numeric
*RST: #H2
<BitCount> integer
0 = marker off, 1 = marker on
Range: 1 to 64
*RST: 2
Example: See Example "Managing waveform files" on page 1020.
Manual operation: See "Marker Mode" on page 311
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:PULSe:DIVider <Divider>
Sets the divider for the pulsed marker signal.
*)
If R&S SMW-B9 is installed, the minimum marker duration depends on the sample/
symbol rate.
See "Marker Minimum Duration" on page 234.
Parameters:
<Divider> integer
Range: 2 (R&S SMW-B10) / 2* (R&S SMW-B9) to 1024
*RST: 2
Example: See Example "Managing waveform files" on page 1020
Manual operation: See "Marker Mode" on page 311
SOURce Subsystem