Remote Control Commands
R&S
®
SMW200A
1104User Manual 1175.6632.02 ─ 30
Parameters:
<Mode> IQ | VECTor | CCDF | PSPectrum | CONStellation | EYEI | EYEQ
*RST: IQ
Example:
BB:GRAP:MODE VECT
Selects the vector diagram graphics mode.
Manual operation: See "Mode" on page 606
[:SOURce<hw>]:BB:GRAPhics:SRATe:MODE <Mode>
Sets how the time resolution of the signal is determined. Maximum resolution corre-
sponds to a diagram covering the entire signal bandwidth. The higher the resolution is,
the shorter the length of the displayed signal segment will be for the specified record-
ing depth.
Parameters:
<Mode> AUTO | FULL | USER
*RST: AUTO
Example:
BB:GRAP:SRAT:MODE FULL
Sets the sample rate mode.
Manual operation: See "Sample Rate Mode" on page 608
[:SOURce<hw>]:BB:GRAPhics:SRATe:USER <User>
(Enabled for BB:GRAPH:SRAT:MODE USER)
Selects the signal bandwidth for the diagram. The setting range moves between the
minimum and maximum bandwidth which is possible for the selected graphical signal
display. The selection is made graphically by moving the pointer.
Parameters:
<User> float
Range: 0.01 to 100
Increment: 0.01
*RST: 10
Default unit: PCT
Example:
BB:GRAP:SRAT:USER 20
sets the sample rate factor.
Example:
BB:GRAP:SRAT:MODE USER
sets the sample rate mode.
Manual operation: See "Sample Rate" on page 608
[:SOURce]:BB:GRAPhics:CLOSe
Closes all graphical signal displays.
Usage:
Event
SOURce Subsystem