Configuring the Internal Baseband Source
R&S
®
SMW200A
310User Manual 1175.6632.02 ─ 30
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:SINE:CREate on page 1032
5.7.3.4 Constant IQ Test Signal
Access:
1. Select "Baseband > ARB > General > Test Signal Form > Const IQ".
2. Select "Create Test Signal".
This dialog provides settings for configuration of a continuous test signal with con-
stant IQ. The I and Q values for each path are adjustable but constant. For more
information, refer to Chapter 5.7.2.2, "ARB Test Signals", on page 298.
If converted to an analog signal, the signal is output directly at the I and Q connec-
tors of the instrument.
Settings:
I Value, Q Value...........................................................................................................310
Generate Signal File................................................................................................... 310
Generate Signal RAM................................................................................................. 310
I Value, Q Value
Enters the value for the I respectively Q component of the test signal.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:CIQ:I on page 1030
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:CIQ:Q on page 1030
Generate Signal File
Generates a signal and saves it as a waveform file on the hard disk. Use the standard
"File Select" function to save the file.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:CIQ:CREate:NAMed on page 1032
Generate Signal RAM
Generates a signal and uses it as output straight away. The instrument saves the file
using a predefined filename.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:CIQ:CREate on page 1032