Remote control commands
R&S
®
RTP
1487User Manual 1337.9952.02 ─ 12
Parameters:
<Slope> POSitive | NEGative | EITHer
See Chapter 22.4.3, "Slope parameter", on page 1147.
*RST: POSitive
Parameters for setting and query:
<SearchName> String parameter, name of the search definition
Usage: Asynchronous command
SEARch:TRIGger:INTerval:DELTa <SearchName>,<WidthDelta>
SEARch:TRIGger:INTerval:DELTa? <SearchName>
Defines a range around the "Interval width" value (see SEARch:TRIGger:
INTerval:WIDTh on page 1488).
Parameters:
<WidthDelta> Range: 0 to 10
Increment: 100E-9
*RST: 0
Default unit: s
Parameters for setting and query:
<SearchName> Search definition
Usage: Asynchronous command
SEARch:TRIGger:INTerval:RANGe <SearchName>,<RangeMode>
SEARch:TRIGger:INTerval:RANGe? <SearchName>
Selects how the range of an interval is defined based on the interval width and delta
(see SEARch:TRIGger:INTerval:WIDTh on page 1488 and SEARch:TRIGger:
INTerval:DELTa on page 1487).
Parameters:
<RangeMode> WITHin | OUTSide | SHORter | LONGer
WITHin
Triggers on pulse intervals inside a given range. The range is
defined by "Interv. width" and "±Delta".
OUTSide
Triggers on intervals outside a given range. The range definition
is the same as for "Within" range.
SHORter
Triggers on intervals shorter than the given "Interv. width".
LONGer
Triggers on intervals longer than the given "Interv. width".
*RST:
OUTSide
Parameters for setting and query:
<SearchName> Search definition
Search