Remote control commands
R&S
®
RTP
1562User Manual 1337.9952.02 ─ 12
TRIGger<m>:I2C:DMIN <Data>
Specifies the data bit pattern, or sets the the start value of a data pattern range.. Enter
the bytes in msb first bit order. The maximum pattern length is 64 bit. Waveform data is
compared with the pattern byte-by-byte.
Parameters:
<Data> Numeric or string pattern, see Chapter 22.4.6, "Bit pattern
parameter", on page 1148. The string parameter accepts the bit
value X (don't care).
Usage: Asynchronous command
TRIGger<m>:I2C:DMAX
<DataTo>
Sets the the end value of an data range if TRIGger<m>:I2C:DCONdition is set to
INRange or OORange.
Parameters:
<DataTo> Numeric or string pattern, see Chapter 22.4.6, "Bit pattern
parameter", on page 1148. The string parameter accepts the bit
value X (don't care).
Usage: Asynchronous command
22.17.3.3 Decode results
To load and acivate a label list, use:
BUS<m>:NEWList on page 1550
BUS<m>:SYMBols on page 1550
BUS<m>:I2C:FRAMe<n>:DATA?...................................................................................1563
BUS<m>:I2C:FCOunt?................................................................................................. 1563
BUS<m>:I2C:FRAMe<n>:AACCess?.............................................................................1563
BUS<m>:I2C:FRAMe<n>:ACCess?............................................................................... 1564
BUS<m>:I2C:FRAMe<n>:ACOMplete?.......................................................................... 1564
BUS<m>:I2C:FRAMe<n>:ADBStart?............................................................................. 1564
BUS<m>:I2C:FRAMe<n>:ADDRess?.............................................................................1565
BUS<m>:I2C:FRAMe<n>:ADEVice?..............................................................................1565
BUS<m>:I2C:FRAMe<n>:AMODe?............................................................................... 1565
BUS<m>:I2C:FRAMe<n>:ASTart?................................................................................. 1566
BUS<m>:I2C:FRAMe<n>:BITRate?............................................................................... 1566
BUS<m>:I2C:FRAMe<n>:RWBStart?.............................................................................1566
BUS<m>:I2C:FRAMe<n>:STATus?................................................................................1567
BUS<m>:I2C:FRAMe<n>:STARt?..................................................................................1567
BUS<m>:I2C:FRAMe<n>:STOP?.................................................................................. 1568
BUS<m>:I2C:FRAMe<n>:SYMBol?............................................................................... 1568
BUS<m>:I2C:FRAMe<n>:BCOunt?............................................................................... 1568
BUS<m>:I2C:FRAMe<n>:BYTE<o>:ACCess?................................................................ 1569
BUS<m>:I2C:FRAMe<n>:BYTE<o>:ACKStart?...............................................................1569
Protocols