Remote control commands
R&S
®
RTP
1600User Manual 1337.9952.02 ─ 12
SEARch:TRIGger:SPI:MISopattern <SearchName>,<MISOPattern>
SEARch:TRIGger:SPI:MISopattern? <SearchName>
SEARch:TRIGger:SPI:MOSipattern <SearchName>,<MOSIPattern>
SEARch:TRIGger:SPI:MOSipattern? <SearchName>
Specifies a data pattern for the MISO or MOSI line, respectively.
Parameters:
<MISOPattern>
<MOSIPattern>
Numeric or string pattern, see Chapter 22.4.6, "Bit pattern
parameter", on page 1148.
Parameters for setting and query:
<SearchName>
Usage: Asynchronous command
Firmware/software: FW 3.30
SEARch:TRIGger:SPI:DPOPerator
<SearchName>,<DataPosOperator>
SEARch:TRIGger:SPI:DPOPerator? <SearchName>
Operator for the data position. You can define an exact position, a position range, or let
the position undefined (ANY).
Parameters:
<DataPosOperator> ANY | OFF | EQUal | GETHan | INRange | RANGe
ANY = OFF, INRange = RANGe
*RST: ANY
Parameters for setting and query:
<SearchName>
Firmware/software: FW 3.30
SEARch:TRIGger:SPI:DPOSition <SearchName>,<DataPosition>
SEARch:TRIGger:SPI:DPOSition? <SearchName>
Sets the number of bits or words before the first word of interest, see also SEARch:
TRIGger:SPI:PALignment. These offset bits/words are skipped. The index 0 is
associated with the first data bit or word.
If the position operator defines a range, also define the last bit/word of interest using
SEARch:TRIGger:SPI:DPTO
Parameters:
<DataPosition> Range: 0 to 32767
Increment: 1
*RST: 0
Parameters for setting and query:
<SearchName>
Firmware/software: FW 3.30