Remote control commands
R&S
®
RTP
1752User Manual 1337.9952.02 ─ 12
BUS<m>:HBTO:FDIF <SrcDiff>
Sets the source of the provided forward differential signal, if BUS<m>:HBTO:FTYP is
set to DIFFerential.
Suffix:
<m>
.
1..4
Parameters:
<SrcDiff> C1W1 | C2W1 | C3W1 | C4W1 | M1 | M2 | M3 | M4 | M5 | M6 |
M7 | M8 | R1 | R2 | R3 | R4
*RST: C1W1
BUS<m>:HBTO:FTYP <SignalType>
Sets the type of forward signal measurement.
Suffix:
<m>
.
1..4
Parameters:
<SignalType> DIFFerential | SINGle
*RST: DIFFerential
BUS<m>:HBTO:RDAM <SrcRevDAminus>
Selects the DA- source of the provided reversed single ended signal, if BUS<m>:
HBTO:RTYP is set to SINGle.
Suffix:
<m>
.
1..4
Parameters:
<SrcRevDAminus> C1W1 | C2W1 | C3W1 | C4W1 | M1 | M2 | M3 | M4 | M5 | M6 |
M7 | M8 | R1 | R2 | R3 | R4
BUS<m>:HBTO:RDAP <SourceRevDAplus>
Selects the DA+ source of the provided reversed single ended signal, if BUS<m>:
HBTO:RTYP is set to SINGle.
Suffix:
<m>
.
1..4
Parameters:
<SourceRevDAplus> C1W1 | C2W1 | C3W1 | C4W1 | M1 | M2 | M3 | M4 | M5 | M6 |
M7 | M8 | R1 | R2 | R3 | R4