Remote control commands
R&S
®
RTP
1814User Manual 1337.9952.02 ─ 12
Parameters:
<ThresDatHyst> Range: 0 to 1
Increment: 0.1
*RST: 0.2
Default unit: V
BUS<m>:RFFE:CLOCk:THReshold:HIGH <ThresClkPos>
Set the positive going threshold (V
TP
) for the clock signal.
Note that the high and low thresholds and the hysteresis values are dependent, so it is
sufficient to define two values for each line.
Suffix:
<m>
.
1..4
Parameters:
<ThresClkPos> Range: 0 to 2.5
Increment: 0.1
*RST: 0.72
Default unit: V
BUS<m>:RFFE:CLOCk:THReshold:LOW <ThresClkNeg>
Set the negative going threshold (V
TN
) for the clock signal.
Note that the high and low thresholds and the hysteresis values are dependent, so it is
sufficient to define two values for each line.
Suffix:
<m>
.
1..4
Parameters:
<ThresClkNeg> Range: 0 to 2.5
Increment: 0.1
*RST: 0.48
Default unit: V
BUS<m>:RFFE:CLOCk:THReshold:HYSTeresis <ThresClkHyst>
Set the hysteresis between V
TP
and V
TN
for the clock signal.
Note that the high and low thresholds and the hysteresis values are dependent, so it is
sufficient to define two values for each line.
Suffix:
<m>
.
1..4
Parameters:
<ThresClkHyst> Range: 0 to 1
Increment: 0.1
*RST: 0.2
Default unit: V
Protocols