Remote control commands
R&S
®
RTP
1817User Manual 1337.9952.02 ─ 12
TRIGger<m>:RFFE:SADD:CONDition............................................................................1822
TRIGger<m>:RFFE:SADD:MIN..................................................................................... 1823
TRIGger<m>:RFFE:SADD:MAX.................................................................................... 1823
TRIGger<m>:RFFE:MASK:CONDition............................................................................1823
TRIGger<m>:RFFE:MASK:MAX....................................................................................1823
TRIGger<m>:RFFE:MASK:MIN..................................................................................... 1824
TRIGger<m>:RFFE:INTerrupt........................................................................................1824
TRIGger<m>:RFFE:ERRor:BP...................................................................................... 1824
TRIGger<m>:RFFE:ERRor:LENGth...............................................................................1824
TRIGger<m>:RFFE:ERRor:NOResponse.......................................................................1824
TRIGger<m>:RFFE:ERRor:PARity.................................................................................1824
TRIGger<m>:RFFE:ERRor:SSC....................................................................................1825
TRIGger<m>:RFFE:ERRor:USEQuence........................................................................ 1825
TRIGger<m>:RFFE:ERRor:GAP....................................................................................1825
TRIGger<m>:RFFE:ERRor:VERSion............................................................................. 1825
TRIGger<m>:RFFE:INTerrupt........................................................................................1825
TRIGger<m>:RFFE:TYPE <Type>
Selects the trigger type for RFFE analysis.
Parameters:
<Type> STARt | STOP | RZWR | RWR | RRD | ERWR | ERRD | ERWL |
ERRL | IRSUM | MSKW | MASOHO | MASW | MASR | MCTW |
MCTR | ERRor
STARt
Triggers on the beginning of a command sequence, exactly after
the slave address. Optionally, you can specify a slave address
condition.
STOP
Triggers on the end of a command sequence, exactly at the start
of the bus park cycle. Optionally, you can specify a slave
address condition.
RZWR
Triggers on Register 0 Write command sequences. Optionally,
you can specify a slave address condition and a data pattern
condition.
RWR
Triggers on Register Write command sequences. Optionally, you
can specify a slave address condition, a register address condi-
tion, and a data pattern condition.
RRD
Triggers on Register Read command sequences. Optionally, you
can specify a slave address condition, a register address condi-
tion, and a data pattern condition.
Protocols