Remote control commands
R&S
®
RTP
1875User Manual 1337.9952.02 ─ 12
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<DataLaneCount> Range: 1 to 4
Increment: 1
*RST: 4
BUS<m>:MPHY:DZERo:SOURce <DataSource>
Sets the source for the lane.
Suffix:
<m>
.
1..4
Parameters:
<DataSource> C1W1 | C2W1 | C3W1 | C4W1 | M1 | M2 | M3 | M4 | M5 | M6 |
M7 | M8 | R1 | R2 | R3 | R4
*RST: C1W1
BUS<m>:MPHY:DONE:SOURce <DataSource>
BUS<m>:MPHY:DTWO:SOURce <DataSource>
BUS<m>:MPHY:DTHRee:SOURce <DataSource>
Selects the source of the corresponding data lane.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<DataSource> C1W1 | C2W1 | C3W1 | C4W1 | M1 | M2 | M3 | M4 | M5 | M6 |
M7 | M8 | R1 | R2 | R3 | R4 | NONE
*RST: DONe: C2W1, DTWo: C3W1, DTHree: C4W1
BUS<m>:MPHY:DZERo:THReshold <ThresholdD0>
BUS<m>:MPHY:DONE:THReshold <ThresholdD1>
BUS<m>:MPHY:DTWO:THReshold <ThresholdD2>
BUS<m>:MPHY:DTHRee:THReshold <ThresholdD3>
Sets the threshold value for the respective lane.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<ThresholdD1>
<ThresholdD2>
<ThresholdD3>
Range: 0 to 1
Increment: 0.01
*RST: 0.1
Default unit: V
Protocols